QUALITYAstro Aluminum Treating's Quality System is based
upon AS 9100B. We are responsive
to customer needs, and work to promptly satisfy our customers'
requirements.
We currently have eleven Rockwell hardness testers and two
Brinell testers for verification of the acceptability of heat
treatments performed. We also have seven conductivity meters for
eddy current testing. In most cases, the combination of hardness and
eddy current test results enables us to confirm that your parts meet
your customer's requirements. All additional metallurgical testing
is performed by certified testing laboratories which have been
approved as suppliers to Astro.
Equipment is calibrated daily and serviced according to ASTM E-8 and MIL-STD 1537.
Certifications of test equipment are traceable to NIST and are
available, upon request.
Our furnaces and ovens are controlled and calibrated in
accordance with AMS 2750.
The additional requirements contained in customer pyrometry
specifications such as
BAC 5621 are also met.